Notes
Notes - notes.io |
nal integrity did not depict any significant differences. Both the groups displayed minimal changes in color, surface texture, and marginal integrity and improved gingival response.
To determine the potential of propolis extract and BBG combination on the quantity of fibroblast growth factor 2 (FGF-2), vascular endothelial growth factor (VEGF), and osteoblasts in the preservation of tooth extraction socket on days 3 and 7.
Laboratory in vivo reseach using animal model.
Fifty-six Cavia cobaya were divided into eight groups containing seven animals in each group. The extraction socket on the lower left incisor was filled with polyethylene glycol (PEG) at a concentration of 2% (Groups I and II) as a control; active materials consisted of propolis extract and PEG (Groups III and IV); active materials consisted of BBG and PEG (Groups V and VI); and active materials consisted of propolis extract, BBG, and PEG (Groups VII and VIII). PYR-41 cost Then, an examination was done using immunohistochemistry to perform an expression of VEGF, FGF2, as well as histology of osteoblasts.
The statistical analysis performed using a one-way ANOVA and Tukey's honestly significant difference test.
Propolis extract, BBG and PEG had the most significant result related to the formation of FGF2, VEGF, and osteoblasts.
The combination of propolis extract with BBG and PEG in socket preservation is effective in increasing the expression of FGF2, VEGF, and osteoblasts.
The combination of propolis extract with BBG and PEG in socket preservation is effective in increasing the expression of FGF2, VEGF, and osteoblasts.
The aim of this work was to evaluate stress distribution on implants in All-on-Four situation with varying distal implant angulations (30°,40°,45°) and varying cantilever lengths (4 mm, 8 mm, 12 mm, 16 mm) in atrophic maxilla using finite element analysis.
A
study, finite element analysis.
Three-dimensional finite element model of an edentulous maxilla restored with a prosthesis supported by four implants was reconstructed to carry out the analysis. Three different configurations, corresponding to 3 tilt degrees of the distal implants (30°, 40°, and 45°) were subjected to 4 loading simulations.
The results of the simulations obtained were evaluated in terms of Von Mises equivalent stress levels at the bone-implant interface.
From a stress-level viewpoint, the 45° model was revealed to be the most critical for peri-implant bone. In all the loading simulations, the maximum stress values were always found at the neck of the distal implants. With increasing distal implant tilt, cantilever length reduces depending on the quality of bone. At 30° angulation of distal implant a maximum cantilever length of 16 mm may be given if the quality of bone is D3 but only 8 mm cantilever may be recommended if bone quality is D4. At 40° angulation, 16 mm in D3 bone and 0 mm in D4 bone whereas at 45° angulation, it reduces to 12 mm in D3 bone and no cantilever is recommended with D4 bone.
The 45° tilt induced higher stress values at the bone-implant interface, especially in the distal aspect, than the other 2 tilts analyzed. Stress values increased with increased cantilever length which was further influenced by the distal implant tilt and the quality of the bone.
The 45° tilt induced higher stress values at the bone-implant interface, especially in the distal aspect, than the other 2 tilts analyzed. Stress values increased with increased cantilever length which was further influenced by the distal implant tilt and the quality of the bone.
A variety of anthropometric techniques have been proposed to determine the correct vertical dimension of occlusion. However, none have reported correlating thumb length (TL) with vertical dimension at rest (VDR). This study aimed to correlate the VDR to measurements of the thumb in a multi-national, multi-centric trial in participants with and without orthodontic treatment and establish a regression equation for each region.
A cross-sectional multi-national, multi-centric correlation trial.
A cross-sectional study was conducted in India and Malaysia with a total of 688 participants. Measurements of thumb and VDR were obtained using a modified Willi's gauge using a standard operating procedure.
Pearson's correlation coefficient was calculated to determine the correlation between TL and VDR. A multiple linear regression was done to correlate VDR from gender, orthodontic treatment, and length of thumb.
Correlation coefficient between TL and VDR in patients with orthodontic treatment was 0.829 and 0.774 in patients without orthodontic treatment. The correlation between TL and VDR in patients with orthodontic treatment in North India was 0.484,
= 0.010 and Malaysia was 0.946,
< 0.001. There were significant correlations between TL and VDR in patients without orthodontic treatment in all regions (
< 0.001). Regression equations were obtained for different ethnic groups for calculating the VDR.
There was an overall positive correlation between TL and VDR in patients with and without orthodontic treatment. The regression equations presented in this article could help clinicians in their clinical practice and researchers to conduct future trials.
There was an overall positive correlation between TL and VDR in patients with and without orthodontic treatment. The regression equations presented in this article could help clinicians in their clinical practice and researchers to conduct future trials.
The aim of this study is to evaluate the efficacy of new material ultraviolet (UV) light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin (Polymethylmethacrylate (PMMA)) to cobalt-chromium (Co-Cr) retentive minor connector.
Comparative evaluation- In-vitro study.
Sixty samples of Co-Cr plates mimicking minor connectors were fabricated. Thirty samples were coated with new material UV light polymerized clear adhesive and cured under UV light source for 10 min. In gun-metal flask, metal plates were placed in the lower compartment over it. Heat cure acrylic resin was packed in the dough stage with the help of clamps and processed according to the manufacturer's instructions. Samples were kept in artificial saliva for 90 days. Shear and tensile bond strengths were calculated of each sample with a Universal testing machine, and results were statistically analyzed. Type of bond failure was observed for each sample under stereomicroscope.
Unpaired t test.
Tensile bond strength, as well as shear bond strength, showed that 0.93 N and 1.64 N respectively for without application of new adhesive was more as compared to that of samples with the application of new adhesive which is 0.75 N and 1.54 N respectively. Bond failure was found to be an adhesive failure in resin-metal interface.
Excellent bonding seen between the new adhesive and acrylic interface but limited effect on the metal interface. To increase bond strength between metal and resin interface, some surface treatment with the metal surface is needed to increase the bonding of the new adhesive to the metal surface.
Excellent bonding seen between the new adhesive and acrylic interface but limited effect on the metal interface. To increase bond strength between metal and resin interface, some surface treatment with the metal surface is needed to increase the bonding of the new adhesive to the metal surface.
The aim of this study is to compare the diagnosis of patients with temporomandibular joint (TMJ) internal derangements which had been diagnosed using Research Diagnostic Criteria/Temporomandibular Disorders (RDC/TMD) with the dynamic high resolution sonography findings.
Axis I section of RDC/TMD form had been applied to participants. Participants were divided into three groups as healthy TMJ, disc displacement with reduction, and disc displacement without reduction. The diagnoses had been compared with the dynamic high-resolution sonography findings.
Twelve of the patients had been treated with laser therapy, whereas 13 patients were treated with stabilization splint. Seventeen patients were treated with anterior repositioning splint (
= 42). After the application of different treatment modalities, the position of the articular disc had been determined with Axis I of RDC/ TMD form and dynamic high-resolution sonography. The findings were compared and statistically analyzed.
Statistical analyses of data were analyzed with Turcosa Cloud (Turcosa Ltd Co, Turkey).
For the right TMJ, pretreatment and posttreatment ultrasonography (USG) diagnoses and RDC/ TMD clinical diagnoses were found similar (κ = 0.125-0.008). No statistically significant relationship was found (
> 0.05). For the left TMJ, pretreatment USG diagnosis and RDC/TMD clinical diagnose were found similar (κ = 0.070). No statistically significant relationship was found (
> 0.05). For the left TMJ, posttreatment USG diagnosis and RDC/TMD clinical diagnose were compared. A statistically significant difference was found (κ = 0.256). A statistically significant relationship was found (
< 0.05).
Axis 1 of RDC/TMD form which is used for the diagnosis of internal derangements and dynamic high resolution sonography was not found in the agreement.
Axis 1 of RDC/TMD form which is used for the diagnosis of internal derangements and dynamic high resolution sonography was not found in the agreement.
The aim of the study is to evaluate the proximal contact tightness (PCT) between single-tooth implant-supported prosthesis (ISP) and the adjacent natural teeth with and without the intervention of the Essix retainer at the end of 1 year.
-experimental study.
Forty patients with a single ISP in the first molar region of the mandibular arch are included in the study who were randomly divided into two groups - Group I (20) those without an intervention of Essix retainer and Group II (20) those with the intervention of Essix retainer (2 mm thickness) (Thermo Vac, Inc. USA) delivered immediately after the restoration of implant with the definitive prosthesis. The groups are further subdivided into Subgroups A (control) and B within Group I and Subgroups C (control) and D within Group II. Mesial and distal PCT values were recorded in each quadrant using the digital force gauge, and values obtained at the end of 1 year were subjected for statistical analysis.
Independent sample
-test was performed.
< 0.05 was taken as statistically significant.
On nonusage of Essix retainer, in comparison to the control group, there were a 57.9% decrease in PCT values for the ISP on mesial contact (
< 0.05) and a 38.9% decrease for the distal contact (
> 0.05), whereas on the usage of Essix retainer, the PCT values for ISP on mesial contact decreased to 25.3% (not significant) and 33.7% on the distal contact (
> 0.05). The incidence of contact loss was found to be 30%, whereas it decreased to 15% on the usage of Essix retainer.
The usage of Essix retainer showed a significant difference in increasing the PCT values, especially on the mesial contact. The incidence of contact loss, which was found to be 30%, decreased to 15% on its usage.
The usage of Essix retainer showed a significant difference in increasing the PCT values, especially on the mesial contact. The incidence of contact loss, which was found to be 30%, decreased to 15% on its usage.
Homepage: https://www.selleckchem.com/products/pyr-41.html
|
Notes.io is a web-based application for taking notes. You can take your notes and share with others people. If you like taking long notes, notes.io is designed for you. To date, over 8,000,000,000 notes created and continuing...
With notes.io;
- * You can take a note from anywhere and any device with internet connection.
- * You can share the notes in social platforms (YouTube, Facebook, Twitter, instagram etc.).
- * You can quickly share your contents without website, blog and e-mail.
- * You don't need to create any Account to share a note. As you wish you can use quick, easy and best shortened notes with sms, websites, e-mail, or messaging services (WhatsApp, iMessage, Telegram, Signal).
- * Notes.io has fabulous infrastructure design for a short link and allows you to share the note as an easy and understandable link.
Fast: Notes.io is built for speed and performance. You can take a notes quickly and browse your archive.
Easy: Notes.io doesn’t require installation. Just write and share note!
Short: Notes.io’s url just 8 character. You’ll get shorten link of your note when you want to share. (Ex: notes.io/q )
Free: Notes.io works for 12 years and has been free since the day it was started.
You immediately create your first note and start sharing with the ones you wish. If you want to contact us, you can use the following communication channels;
Email: [email protected]
Twitter: http://twitter.com/notesio
Instagram: http://instagram.com/notes.io
Facebook: http://facebook.com/notesio
Regards;
Notes.io Team