Notes
Notes - notes.io |
PET/CT has become a preferred imaging modality over PET-only scanners in clinical practice. However, along with the significant improvement in diagnostic accuracy and patient throughput, pitfalls on PET/CT are reported as well. BMS-986165 cost This review provides a general overview on the potential influence of the limitations with respect to PET/CT instrumentation and artifacts associated with the modality integration on the image appearance and quantitative accuracy of PET. Approaches proposed in literature to address the limitations or minimize the artifacts are discussed as well as their current challenges for clinical applications. Although the CT component can play an important role in assisting clinical diagnosis, we concentrate on the imaging scenarios where CT is used to provide auxiliary information for attenuation compensation and scatter correction in PET.From the outset of the COVID-19 pandemic we, the nuclear medicine (NM) community, expediently mobilized to enable continuity of essential services to the best of our abilities. For example, we effectuated adapted guidelines for NM standard operating procedures (SOPs) and enacted heightened infection protection measures for staff, patients, and the public, alike. Challenges in radionuclide supply chains were identified and often met. NM procedural volumes declined globally and underwent restoration of varying degrees, contingent upon local contexts. Serial surveys have gauged and chronicled such geographical variance of the impact of COVID-19 on NM service delivery and, though it may be too early to fully understand the long-term consequences of reduced NM services, overall, we can certainly expect that this era adversely affected the management of many patients afflicted with non-communicable diseases. Today we are unquestionably better prepared to face unforeseen outbreaks, but a degree of uncertainty lingerWhich ones? Practices must remain ready for possible new peaks or variants of the roiling COVID-19 contagion and for the emergence of potential new pathogens that may incite future outbreaks or pandemics. Communications technologies are here to stay and will continue to be used in a broad spectrum of applications, from telemedicine to education, but how best? NM departments must align synergistically with these trends, considering what adaptations to a more virtual professional environment should not only last but be further innovated. The paper aims to provide recent history, analysis, and a springboard for continued constructive dialogue. To best navigate the future, NM must continue to learn from this crisis and must continue to bring new questions, evidence, ideas, and warranted systematic updates to the figurative table.SARS-CoV-2 virus may cause COVID-19 disease, which causes mild-to-moderate disease in 80% of laboratory-confirmed cases which may be community-managed. A considerable age-dependent mortality is seen among elderly and other at-risk populations but among young and healthy individuals it is less then 0.5%. Long-term health issues have been reported following severe COVID-19 requiring hospitalization as well as after cases of mild COVID-19 without hospitalization. Upon receiving COVID-19 suspected patients at hospitals, patients should be isolated and PPE should be worn by all health staff when in contact with the patients. Additionally, patients are tested for the presence of SARS-CoV-2 RNA by PCR, and blood samples are drawn. Imaging is not pivotal for the diagnosis, but chest X-ray is a relevant examination for all and is used to determine severity and treatment need Abnormal findings on CT scans are found in most patients, most frequently peripheral ground-glass opacity and bilateral patchy shadowing are present. Patients are, according to their needs and risks, treated with oxygen therapy, anticoagulation therapy, steroids, antivirals, or immunosupressive drugs on special indications. Convalescent plasma therapy and monoclonal antibodies have a limited role in the treatment, mostly in severely immunocompromised patients. Patients with long-term sequelae should be evaluated in a post-COVID outpatient clinic. The most frequent reported symptoms include cognitive impairment, dyspnea, loss of smell and taste, and mental and physical fatigue although a wide spectrum of symptoms from other organ systems are also reported. The current treatment is based on symptom relief and rehabilitation as there is no documented specific medical treatment.Hybrid FDG PET/CT plays a vital role in oncologic imaging and has been widely adopted for the staging and restaging of a variety of malignancies. Its diagnostic value in urogenital malignancies is less well-known, not at least because of the variable FDG avidity of these tumor entities, the sites of these tumors, and technical challenges associated with sequential imaging of CT and PET. PET/CT interpretation thus can be especially challenging and is associated with many pitfalls, which can lead to both false-positive and false-negative diagnoses as well as incorrect assessment of metabolic change following therapy. Currently, FDG PET/CT is not the standard of care for the initial diagnosis or staging of early-stage or low-risk urogenital cancers; however, it can help evaluate distant metastatic disease, response to therapy, and disease recurrence in high-risk patients. Knowledge of imaging features of tumor metabolic avidity and pitfalls is essential for accurate interpretation.18F- Fluoro-deoxyglucose positron emission computed tomography (18F-FDG PET CT) is an established modality used mainly in oncology. Though it has widespread oncologic indications, it is not tumor specific. Apart from the physiological distribution, uptake of FDG may be seen in many benign conditions, including infection and inflammation in children and adults. Performing and acquiring a technically adequate PET CT study may be more challenging in children. Proper preparation and an acceptable imaging protocol will help to avoid re-acquisition and in minimizing the radiation exposure. Sound knowledge of the physiological variants and benign conditions that are specific to the pediatric population will aid in correct interpretation of the PET CT study. It is important that radiologists and Nuclear Medicine physicians who report these studies are well-acquainted with these pitfalls to avoid false positive studies.
Read More: https://www.selleckchem.com/products/bms-986165.html
|
Notes is a web-based application for online taking notes. You can take your notes and share with others people. If you like taking long notes, notes.io is designed for you. To date, over 8,000,000,000+ notes created and continuing...
With notes.io;
- * You can take a note from anywhere and any device with internet connection.
- * You can share the notes in social platforms (YouTube, Facebook, Twitter, instagram etc.).
- * You can quickly share your contents without website, blog and e-mail.
- * You don't need to create any Account to share a note. As you wish you can use quick, easy and best shortened notes with sms, websites, e-mail, or messaging services (WhatsApp, iMessage, Telegram, Signal).
- * Notes.io has fabulous infrastructure design for a short link and allows you to share the note as an easy and understandable link.
Fast: Notes.io is built for speed and performance. You can take a notes quickly and browse your archive.
Easy: Notes.io doesn’t require installation. Just write and share note!
Short: Notes.io’s url just 8 character. You’ll get shorten link of your note when you want to share. (Ex: notes.io/q )
Free: Notes.io works for 14 years and has been free since the day it was started.
You immediately create your first note and start sharing with the ones you wish. If you want to contact us, you can use the following communication channels;
Email: [email protected]
Twitter: http://twitter.com/notesio
Instagram: http://instagram.com/notes.io
Facebook: http://facebook.com/notesio
Regards;
Notes.io Team