Notes
Notes - notes.io |
Genome wide association studies allowed prediction of 17 candidate genes for association with nitrogen use efficiency. Novel information obtained may provide better understanding of genomic controls underlying germplasm variations for this trait in Indian mustard. Nitrogen use efficiency (NUE) of Indian mustard (Brassica juncea (L.) Czern & Coss.) is low and most breeding efforts to combine NUE with crop performance have not succeeded. Underlying genetics also remain unexplored. We tested 92 SNP-genotyped inbred lines for yield component traits, N uptake efficiency (NUPEFF), nitrogen utilization efficiency (NUTEFF), nitrogen harvest index (NHI) and NUE for two years at two nitrogen doses (N
without added N and N
added @100kg/ha). Genotypes IC-2489-88, M-633, MCP-632, HUJM 1080, GR-325 and DJ-65 recorded high NUE at low N. These also showed improved crop performance under high N. One determinate mustard genotype DJ-113 DT-3 revealed maximum NUTEFF. Genome wide association studies (GWAS) facilitated r B07 and B08) harbored many useful loci. We also used regional association mapping (RAM) to supplement results from GWAS. Annotation of the genomic regions around peak SNPs helped to predict several gene candidates for root architecture, N uptake, assimilation and remobilization. CAT9 (At1g05940) was consistently envisaged for both NUE and NUPEFF. Major N transporter genes, NRT1.8 and NRT3.1 were predicted for explaining variation for NUTEFF and NUPEFF, respectively. Most significant amino acid transporter gene, AAP1 appeared associated with NUE under limited N conditions. RO5126766 mw All these candidates were predicted in the regions of high linkage disequilibrium. Sequence information of the predicted candidate genes will permit development of molecular markers to aid breeding for high NUE.
To assess whether asingle training session for general practitioners (GPs) improves the evidence-based drug treatment of heart failure (HF) patients, especially of those with HF with reduced ejection fraction (HFrEF).
Acluster randomised controlled trial was performed for which patients with established HF were eligible. Primary care practices (PCPs) were randomised to care-as-usual or to the intervention group in which GPs received ahalf-day training session on HF management. Changes in HF medication, health status, hospitalisation and survival were compared between the two groups. Fifteen PCPs with 200 HF patients were randomised to the intervention group and 15PCPs with 198 HF patients to the control group. Mean age was 76.9 (SD 10.8) years; 52.5% were female. On average, the patients had been diagnosed with HF 3.0 (SD 3.0) years previously. In total, 204 had HFrEF and 194 HF with preserved ejection fraction (HFpEF). In participants with HFrEF, the use of angiotensin-converting enzyme inhibitors/angiotensin receptor blockers decreased in 6months in both groups [5.2%; (95% confidence interval (CI) 2.0-10.0)] and 5.6% (95% CI 2.8-13.4)], respectively [baseline-corrected odds ratio (OR) 1.07 (95% CI 0.55-2.08)], while beta-blocker use increased in both groups by 5.2% (95% CI 2.0-10.0) and 1.1% (95% CI 0.2-6.3), respectively [baseline-corrected OR 0.82 (95% CI 0.42-1.61)]. For health status, hospitalisations or survival after 12-28months there were no significant differences between the two groups, also not when separately analysed for HFrEF and HFpEF.
Ahalf-day training session for GPs does not improve drug treatment of HF in patients with established HF.
A half-day training session for GPs does not improve drug treatment of HF in patients with established HF.Acceptance and commissioning of a linear accelerator is the process of preparing it for clinical use. One of the initial important dosimetric tasks for X-ray beam set-up and use is to optimise the trajectory of the electron beam before it hits the target (focal spot). The main purpose of this study is to characterise the effect of the focal spot position (offset) on the photon beam symmetry and centre position, as well as on linac radiation isocentre size and position for an Elekta Synergy® linac. For this machine, the initial electron beam steering control items 2T and Bending F were altered to steer the beam in both transverse and radial directions respectively. The IC Profiler™ was utilised to measure the photon beam symmetry and centre position; the electronic portal imaging device (EPID) and the authors' published ready-to-go procedure were used to measure the focal spot offset; and the radiation isocentre size and position were measured using the EPID, the Elekta ball-bearing phantom and in-house softwaowed that focal spot offsets and beam symmetries in terms of absolute deviations were on average 0.08 ± 0.05 mm (1SD) and 0.70 ± 0.27% (1SD) respectively.During interventional cardiological procedures, operators are exposed to patients' scatter radiation. Therefore, we measured the radiation exposure of the operator's eyeball, thyroid, and chest wall during angiography. We used the optically stimulated luminescence dosimeter in the anthropomorphic phantom and developed Monte Carlo simulations using the Korean human voxel phantom. At 15 frames/s, the radiation dose of the operator's right eyeball (RE), left eyeball (LE), thyroid (T), and chest wall (CW) at the femoral artery puncture position (FAPP) with protective equipment (PE) was 0.015, 0.16, 0.012, and 0.014 mGy, respectively. At 7.5 frames/sec, the radiation dose of the operator's RE, LE, T, and CW at FAPP with PE was 33.33%, 18.75%, 52.94%, and 45.00% lower than that of those at the radial artery puncture position (RAPP), respectively. At 15 frames/s, the radiation dose of the operator's RE, LE, T, and CW at RAPP without PE was 1.76 times, 2.23 times, 2.76 times, and 2.05 times higher than that of those with PE. Per the simulation results, the absorbed radiation dose of the eye ball, thyroid gland, and myocardium of the heart at FAPP with and without PE under 15 frame/s was 9.68%, 13.04%, 8.33% and 9.98%, 6.00%, 8.82% lower than at RAPP under similar conditions. Effective measures for occupational radiological protection are lower frame rate exposure, increased distance from the X-ray source, and PE use. Radiologist protection in interventional cardiology cannot be handled independently of patient protection, owing to several correlations; thus, reducing the patient dose will reduce the operator dose.
Website: https://www.selleckchem.com/products/ro5126766-ch5126766.html
|
Notes is a web-based application for online taking notes. You can take your notes and share with others people. If you like taking long notes, notes.io is designed for you. To date, over 8,000,000,000+ notes created and continuing...
With notes.io;
- * You can take a note from anywhere and any device with internet connection.
- * You can share the notes in social platforms (YouTube, Facebook, Twitter, instagram etc.).
- * You can quickly share your contents without website, blog and e-mail.
- * You don't need to create any Account to share a note. As you wish you can use quick, easy and best shortened notes with sms, websites, e-mail, or messaging services (WhatsApp, iMessage, Telegram, Signal).
- * Notes.io has fabulous infrastructure design for a short link and allows you to share the note as an easy and understandable link.
Fast: Notes.io is built for speed and performance. You can take a notes quickly and browse your archive.
Easy: Notes.io doesn’t require installation. Just write and share note!
Short: Notes.io’s url just 8 character. You’ll get shorten link of your note when you want to share. (Ex: notes.io/q )
Free: Notes.io works for 14 years and has been free since the day it was started.
You immediately create your first note and start sharing with the ones you wish. If you want to contact us, you can use the following communication channels;
Email: [email protected]
Twitter: http://twitter.com/notesio
Instagram: http://instagram.com/notes.io
Facebook: http://facebook.com/notesio
Regards;
Notes.io Team