Results showed an increased risk of developing any infection (relative risk [RR]= 1.71 ± 0.16) and S aureus infection (RR= 2.79 ± 0.45) after orthopedic surgery without previous nares and whole-body decolonization. Focusing exclusively on elective TJA, there was an increased risk of developing any infection (RR= 1.70 ± 0.17) and S aureus infection (RR= 2.18 ± 0.41) if no decolonization is performed. All strategies appeared to be cost-effective, although universal decolonization without screening seemed to be the most advantageous.
Preoperative S aureus screening/decolonization protocol lowered the risk of infection after elective orthopedic and TJA surgeries. However, further studies are needed to determine optimal clinical and cost-effective methodologies.
Preoperative S aureus screening/decolonization protocol lowered the risk of infection after elective orthopedic and TJA surgeries. However, further studies are needed to determine optimal clinical and cost-effective methodologies.
Metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) has recently gained increased utilization as a screening modality in patients with a total hip arthroplasty (THA). Fluid collections have been documented in asymptomatic patients with various bearing surfaces. find more The purpose of this study is to determine the frequency and types of MARS MRI-documented abnormalities in asymptomatic patients with a ceramic-on-ceramic (CoC) THA.
Thirty-seven patients (42 hips) with a minimum 2-year follow-up after THA with CoC THA implants were enrolled in this study. The inclusion criteria were the absence of hip pain and the availability of appropriate follow-up radiographs. All patients underwent a MARS MRI. Abnormalities were documented using a previously described method.
Fluid collections were observed in 8 (19%) asymptomatic hips in this cohort. Four of the 8 hips demonstrated intracapsular synovitis, and 3 of these hips had a thickened synovium. Extra-articular fluid collections with direct intra-articular communication were identified in 4 hips, with 2 of these hips demonstrating synovial thickening. No signs of osteolysis were noted on radiographs or the MARS MRI scans.
Asymptomatic fluid collections occur in patients after CoC THA similar to other bearing surfaces. We continue to follow these patients in an effort to determine the clinical significance and natural history of these findings.
Diagnostic Level IV.
Diagnostic Level IV.
Although the pelvic vascular injury caused by a transacetabular screw is rare, it is a major local complication of total hip arthroplasty. We aimed to obtain anthropometric data about the safe zone for the placement of transacetabular screws by analyzing the three-dimensional (3D) reconstruction model and determine the safe length of transacetabular screws by performing the 3D simulated surgery.
We reviewed 50 hips of 25 patients who underwent lower extremity angiographic computed tomography scans retrospectively. We reconstructed the 3D models of 50 hips with normal pelvic bone and vascular status using the customized computer software. We measured the central angle and safe depth of the safe zone of the transacetabular screws on the 3D models. We also performed the 3D simulated surgery to confirm the safe length of screws in each hole of the customized cup implant.
The measured central angle of the posterior-superior area was 79.5°. And we determined a mean safe depth of 49.8 mm in the safe zone, with a central angle of 47.7°. During the 3D simulated surgery, we determined a mean safe length of the transacetabular screw of 43.3 mm when applied to a lateral hole on a line bisecting the posterior-superior area.
Although our study was limited by the use of a virtual computer program, the quantitative measurements obtained can help reduce the incidence of pelvic vascular injury during transacetabular screw fixation in total hip arthroplasty.
Although our study was limited by the use of a virtual computer program, the quantitative measurements obtained can help reduce the incidence of pelvic vascular injury during transacetabular screw fixation in total hip arthroplasty.
The clinical and radiographic results of cementless total hip arthroplasty using a 32-mm cobalt-chromium head on remelted highly cross-linked polyethylene (HXLPE) and a tapered, fiber metal proximally coated femoral stem were evaluated at a mean follow-up of 12 years.
A total of 57 cementless total hip arthroplasties using remelted HXLPE combined with a 32-mm cobalt-chromium head, and a tapered, fiber metal proximally coated femoral stem were performed from October 2004 to December 2006. Clinical evaluation was performed using the Merle d'Aubigné and Postel scoring system. Standardized anteroposterior and lateral radiographs of the pelvis and femur without weight-bearing were analyzed. Radiographic measurements of two-dimensional femoral head penetration into the polyethylene were performed with a computerized method. The steady-state wear rates were measured based on the radiographs from the first year after surgery to the final follow-up.
The mean Merle d'Aubigné and Postel score improved significantly from 10.7 points preoperatively to 15.6 postoperatively (P < .001). No osteolysis was found around the implant. Stem fixation in all cases showed stable bone ingrowth. Third-degree stress shielding was found in 46% of all stems. The total head penetration rate was 0.05 mm/y, and the steady-state wear rate was 0.01 mm/y. The Kaplan-Meier survivorship with the end point of revision was 95% (95% confidence interval, 85%-98%) at 12 years.
A 32-mm cobalt-chromium head on remelted HXLPE demonstrated low wear properties, and a tapered, fiber metal proximally coated femoral stem showed good results at long-term follow-up.
A 32-mm cobalt-chromium head on remelted HXLPE demonstrated low wear properties, and a tapered, fiber metal proximally coated femoral stem showed good results at long-term follow-up.
Health care systems are concerned that facility reimbursements will be reduced based on patient length of stay (LOS) of <2 midnights with the removal of total knee arthroplasty (TKA) from the inpatient-only list. The purpose of this study was to evaluate the effect of LOS and postdischarge disposition on facility reimbursement.
We evaluated a consecutive series of 470 primary Medicare TKA patients performed at a single institution from 2018 to 2019. We analyzed facility reimbursement based on patient LOS and discharge disposition. Descriptive statistics were analyzed using chi-square test, analysis of variance, and Student ttest calculations.
Overall, the facility was fully reimbursed in 401 patients (85%) at a mean of $11,169. The facility received full reimbursement for 323 of 326 (99%) patients with an LOS of <2 midnights who were discharged to home at a mean of $11,156. This reimbursement was significantly (P < .001) higher than patients who had an LOS <2 midnights who were discharged with home health (mean, $9773) or to a facility (mean, $10,095).
Here's my website: https://www.selleckchem.com/Bcl-2.html
![]() |
Notes is a web-based application for online taking notes. You can take your notes and share with others people. If you like taking long notes, notes.io is designed for you. To date, over 8,000,000,000+ notes created and continuing...
With notes.io;
- * You can take a note from anywhere and any device with internet connection.
- * You can share the notes in social platforms (YouTube, Facebook, Twitter, instagram etc.).
- * You can quickly share your contents without website, blog and e-mail.
- * You don't need to create any Account to share a note. As you wish you can use quick, easy and best shortened notes with sms, websites, e-mail, or messaging services (WhatsApp, iMessage, Telegram, Signal).
- * Notes.io has fabulous infrastructure design for a short link and allows you to share the note as an easy and understandable link.
Fast: Notes.io is built for speed and performance. You can take a notes quickly and browse your archive.
Easy: Notes.io doesn’t require installation. Just write and share note!
Short: Notes.io’s url just 8 character. You’ll get shorten link of your note when you want to share. (Ex: notes.io/q )
Free: Notes.io works for 14 years and has been free since the day it was started.
You immediately create your first note and start sharing with the ones you wish. If you want to contact us, you can use the following communication channels;
Email: [email protected]
Twitter: http://twitter.com/notesio
Instagram: http://instagram.com/notes.io
Facebook: http://facebook.com/notesio
Regards;
Notes.io Team