Notes![what is notes.io? What is notes.io?](/theme/images/whatisnotesio.png)
![]() ![]() Notes - notes.io |
RESULTS There was a statistically significant difference between postoperative first day thrombocyte (K/µL) (P = .005), postoperative first day PMI (P = .014), postoperative first day leukocyte (K/µL) (P = .001), postoperative first day Hb (g/dL) (P = .001), postoperative third day thrombocyte (K/µL) (P = .003), postoperative third day PMI (P = .031), postoperative third day leukocyte (K/µL) (P = .004), and postoperative seventh day leukocyte (K/µL) (P = .002). There was no meaningful relationship between PMI and early postoperative complications. CONCLUSION We think PMI is a more valuable indicator than MPV as an inflammation marker in cardiac surgery. In our opinion, PMI is a cheap and valuable inflammation marker that can be used in coronary surgery that can be obtained from routine hemogram test and can easily be evaluated. 2020 Forum Multimedia Publishing, LLCA 67-year-old man with a 3-year history of dyspnea on exertion arrived to our institution with discontinuous palpitations and short breath. He was diagnosed with congenital coronary artery fistula (CAF). Angiography revealed 3 giant aneurysmal formations and coronary artery calcification. We report a case of successful repair of CAF with a giant coronary aneurysm by closing the orifice and resecting the aneurysm and reconstructing the left coronary artery. The surgical procedure included closure from within a vessel dilated by aneurysm and excision of the aneurysm. We were able to completely obliterate the fistula and preserve the normal blood flow through the coronary arteries post operation. The postoperative course was eventful, but the patient was discharged home. The patient was doing well at his 28-month follow-up visit. 2020 Forum Multimedia Publishing, LLCBACKGROUND The GuidezillaTM support extension catheter is designed to provide extra back-up support and efficient device delivery during complex percutaneous coronary interventions (PCIs), such as in treatment of severe calcification, tortuous chronic total occlusions (CTOs), and coronary anomalies. The aim of this study was to describe our initial experience with the GuidezillaTM extension catheter in the treatment of complex coronary artery lesions. METHODS This study retrospectively analyzed data from 165 PCI cases that used the GuidezillaTM guide extension catheter between March 2015 and August 2017. We collected patient clinical characteristics, target lesion characteristics, and procedural details. RESULTS Eighty-six percent of patients had complex Type C lesions, and 13.9% had Type B lesions. Lesion length ranged from 8 mm to 130 mm (≤ 20 mm, 15.4%; 20-40 mm, 35.8%; > 40 mm, 49.1%). The right coronary artery (59.2%) was the most common intervention vessel followed by the left ascending artery (30.6%) and the left circumflex artery (10.2%). CTO accounted for 38% of all lesions, followed by distortions (28%), heavy calcification (24%), proximal stent thrombosis (9%), and coronary artery origin anomalies (1%). A total of 142 patients underwent successful PCI using the GuidezillaTM extension catheter. The success rate was 86%. buy SecinH3 CONCLUSION The GuidezillaTM guide extension catheter was an effective and safe technique in the transradial treatment of complex coronary lesions. Use of the GuidezillaTM guide extension catheter can shorten the procedure time and ensure overall procedural success with a reduced complication rate in cases where adequate progress using angioplasty devices has not been achieved. 2020 Forum Multimedia Publishing, LLCA variety of pathologies may affect the most important bone to cardiac surgeons. In this paper, 3 interesting cases of different pathology and aetiology are presented and discussed. 2020 Forum Multimedia Publishing, LLCLipomas are the most common type of soft tissue tumors. They mainly are located in subcutaneous tissue in the body, including the heart. The cardiac location of lipomas is rare, mostly asymptomatic, and can cause life-threatening complications by rapid growth. The clinical symptoms, when present, occur in evolution with the growth in size, depending upon the location and degree of invasion in the endocardium. We present the case of a 63-year-old male patient with a large intrapericardial lipoma with an unusual location, originating from the left atrial roof. The initial symptoms of the patient were shortness of breath, dizziness, and mild dyspnea. Transthoracic echocardiography (TTE) was the first line diagnosis method, followed by computed tomography (CT); both showed a large posterior intrapericardial mass. Resection of a 12/8/5 cm lipomatous tumor mass was performed via median sternotomy, under cardiopulmonary bypass (CPB) on the beating heart. Histopathologic examination revealed the presence of diffuse proliferation of large- and medium-sized mature adipocytes consistent with the diagnosis of pericardial lipoma. The patient was discharged at home on the seventh postoperative day, with a marked improvement of his clinical state and effort tolerance. He did not present evidence of recurrence at his 1-year follow up. 2020 Forum Multimedia Publishing, LLCBACKGROUND The optimal length of saphenous vein grafts can be challenging in surgical coronary revascularization. It is the cornerstone for graft patency. In this study, we tried to demonstrate the value of 3D printing in determining optimal saphenous graft length. METHODS Sixteen patients who underwent bypass surgery with only vein grafts were examined. Patients' measurements of graft lengths were obtained from postoperative CT images and from both 3D print models manually with plastic tubes and via 3D print digital images of Mimics software during segmentation. Another measurement was done using the Fit Centerline tool in the analysis module of Mimics software after segmentation. These 3 measurements were compared. RESULTS There was a statistically significant difference between 3 measurement methods for each graft length (P .05). CONCLUSION 3D printing models and their software may be used to determine optimal saphenous graft length and the anastomosis site to decrease operation time. It can be deducted from these results that 3D printing is a promising method for reducing operator dependent variables in adjusting graft size and finding optimal anastomosis sites.
Homepage: https://www.selleckchem.com/products/secinh3.html
![]() |
Notes is a web-based application for online taking notes. You can take your notes and share with others people. If you like taking long notes, notes.io is designed for you. To date, over 8,000,000,000+ notes created and continuing...
With notes.io;
- * You can take a note from anywhere and any device with internet connection.
- * You can share the notes in social platforms (YouTube, Facebook, Twitter, instagram etc.).
- * You can quickly share your contents without website, blog and e-mail.
- * You don't need to create any Account to share a note. As you wish you can use quick, easy and best shortened notes with sms, websites, e-mail, or messaging services (WhatsApp, iMessage, Telegram, Signal).
- * Notes.io has fabulous infrastructure design for a short link and allows you to share the note as an easy and understandable link.
Fast: Notes.io is built for speed and performance. You can take a notes quickly and browse your archive.
Easy: Notes.io doesn’t require installation. Just write and share note!
Short: Notes.io’s url just 8 character. You’ll get shorten link of your note when you want to share. (Ex: notes.io/q )
Free: Notes.io works for 14 years and has been free since the day it was started.
You immediately create your first note and start sharing with the ones you wish. If you want to contact us, you can use the following communication channels;
Email: [email protected]
Twitter: http://twitter.com/notesio
Instagram: http://instagram.com/notes.io
Facebook: http://facebook.com/notesio
Regards;
Notes.io Team