Notes
![]() ![]() Notes - notes.io |
The natural killer (NK) cell population was significantly decreased only in DPs from teeth treated with fibrin-chitosan hydrogel. Immunolabeling analysis of the DP/hydrogel interface showed accumulation of neutrophil granulocytes in contact with both hydrogels 1 d after treatment. The DP close to this granulocyte area contained M2 but no M1 macrophages. These data collectively demonstrated that fibrin-chitosan hydrogels induced an inflammatory/immune response similar to that of the fibrin hydrogel. The results confirmed the potential clinical use of fibrin-chitosan hydrogel as a new scaffold for vital-pulp therapies.The evidence base is growing regarding proximal fibular osteotomy. Most studies show that the pain relief and improvement in terms of radiology is statistically significant. More understandable biomechanical theories explaining this improvement are appearing. Because it has a low complication rate and is relatively easy to execute, proximal fibular osteotomy should definitely be considered in any algorithm for the treatment of medial compartment osteoarthritis of the knee. [Orthopedics. 2020;43(6)e627-e631.].The "July effect" refers to the assumed increased risk of complications during the months when medical school graduates transition to residency programs. The actual existence of a July effect is controversial. With this study, the authors sought to determine whether evidence exists for the presence of a July effect among total joint arthroplasty (TJA) procedures. The 2013 and 2014 Nationwide Readmission Databases were combined and all index primary and revision arthroplasty procedures were identified, and then patients from December were excluded. Thirty-day readmission rates, time to readmission, and readmission costs were analyzed by index procedure month and index procedure type. A total of 1,193,034 procedures (index primary n=1,107,657; revision arthroplasty n=85,377) were identified. Among all procedure types, 46,674 (3.9%) 30-day readmissions were observed. Among all procedures, an index procedure with a discharge in July resulted in the highest monthly readmission rate of the year (4.2%), which was significantly higher than the mean annual readmission rate (P less then .0001). This effect was most pronounced for primary total knee arthroplasty (3.9% vs 3.6%, P less then .0001). When stratifying results into teaching vs nonteaching hospitals, the highest readmission rate occurred if the index procedure occurred at a nonteaching hospital in July (4.5%, P less then .0001). These data provide evidence that a July effect appears to exist for TJA procedures and is most pronounced at nonteaching institutions. Based on published mean readmission costs, the total annualized cost variation attributable to the higher readmission rate for primary TJA procedures in July is approximately $18.6 million. [Orthopedics. 2020;43(6)e543-e548.].Patellar crepitus and clunk (PCC) is a known complication in total knee arthroplasty (TKA) and the cause of dissatisfaction. Patellofemoral articulations have reportedly been optimized in newer TKAs. This study compared the incidence of PCC between a historical and modern TKA design. A single-surgeon retrospective review of primary PFC Sigma (DePuy Synthes, Warsaw, Indiana) or Attune TKA (DePuy Synthes) was performed. A total of 114 PFC Sigma and 103 Attune implants were analyzed at a mean 3.2 years follow-up for overall PCC, painful PCC, anterior knee pain (regardless of crepitus), and PCC necessitating revision. Similar rates of overall PCC (14.6% vs 20.2%, P=.803), painful PCC (8.7% vs 6.1%, P=.605), and anterior knee pain (15.5% vs 9.7%, P=.219) were observed in the Attune and PFC Sigma groups, respectively. No clinically significant differences in range of motion, pain, or Knee Society Scores were found between groups. Subgroup analyses of mobile vs fixed bearing PFC Sigma implants demonstrated higher rates of overall PCC (32.4% vs 15.0%, P=.043), painful PCC (20.6% vs 5.0%, P=.016), anterior knee pain (17.6% vs 1.3%, P=.003), and crepitus requiring revision surgery (17.6% vs 1.3%, P=.003) for mobile bearing PFC Sigma implants. No difference was found in the rates of anterior knee pain or PCC between the PFC Sigma and Attune implants. Subgroup analysis suggests that a mobile bearing PFC Sigma implant results in higher PCC. The authors believe the true incidence of anterior knee pain and PCC is underreported in the literature because many outcome measures do not capture these complications. [Orthopedics. selleck products 2020;43(6)e508-e514.].Scapular notching remains a concern with both medialized and lateralized reverse shoulder arthroplasty (RSA) designs. Few studies have directly compared the rate of notching among various designs. The purpose of this study was to compare a single surgeon's rate of scapular notching in relation to RSA design. A total of 156 primary RSAs were performed for cuff tear arthropathy or osteo-arthritis with rotator cuff insufficiency by a single surgeon. Follow-up was controlled to between 3 and 5 years. Shoulders were grouped according to implant design medialized center of rotation (CoR; n=17), lateralized CoR (n=14), and lateralized humerus (n=125). Objective clinical outcomes, patient-reported outcomes, and radiographic outcomes were compared. Scapular notching occurred more frequently with medialized CoR (82%) and lateralized CoR (57%) designs compared with a lateralized humerus design (22%; P less then .001). Mean notching grade was also lower in the lateralized humerus design (0.2) compared with the medialized CoR (2.1; P less then .001) and lateralized CoR (1.1; P=.01) designs. Postoperative pain, range of motion, and patient-reported outcomes were not significantly different among groups. A low rate of reoperation was seen in all groups. The lateralized humeral RSA design showed less frequent and less severe scapular notching compared with medialized CoR and lateralized CoR designs. There were no observed differences in range of motion or patient-reported outcomes between different implant designs. [Orthopedics. 2020;43(6)e585-e591.].Patients with metastatic spinal tumors often experience paralysis caused by spinal cord compression. Several studies have investigated metastatic lesion-related spinal cord compression. This study is the first to examine the relationship between the epidural spinal cord compression (ESCC) scale, which measures circumferential compression, and the functional outcomes of treatment, which were assessed at regular intervals after treatment until death. A total of 191 patients who had grade D or worse paralysis on the American Spinal Injury Association (ASIA) classification scale and a grade 1b or more severe cord compression on the ESCC scale were included in the study. Patients had been treated with surgery combined with radiotherapy (n=146) or radiotherapy alone (n=45). Three spinal surgeons assessed the ESCC grade of for patient, and the grade agreed to by at least 2 surgeons was adopted. After 4 weeks, re-evaluations were conducted by the same examiners. The authors also calculated the mean kappa coefficients for inter- and intra-examiner variability (0.
Read More: https://www.selleckchem.com/products/LY2228820.html
![]() |
Notes is a web-based application for online taking notes. You can take your notes and share with others people. If you like taking long notes, notes.io is designed for you. To date, over 8,000,000,000+ notes created and continuing...
With notes.io;
- * You can take a note from anywhere and any device with internet connection.
- * You can share the notes in social platforms (YouTube, Facebook, Twitter, instagram etc.).
- * You can quickly share your contents without website, blog and e-mail.
- * You don't need to create any Account to share a note. As you wish you can use quick, easy and best shortened notes with sms, websites, e-mail, or messaging services (WhatsApp, iMessage, Telegram, Signal).
- * Notes.io has fabulous infrastructure design for a short link and allows you to share the note as an easy and understandable link.
Fast: Notes.io is built for speed and performance. You can take a notes quickly and browse your archive.
Easy: Notes.io doesn’t require installation. Just write and share note!
Short: Notes.io’s url just 8 character. You’ll get shorten link of your note when you want to share. (Ex: notes.io/q )
Free: Notes.io works for 14 years and has been free since the day it was started.
You immediately create your first note and start sharing with the ones you wish. If you want to contact us, you can use the following communication channels;
Email: [email protected]
Twitter: http://twitter.com/notesio
Instagram: http://instagram.com/notes.io
Facebook: http://facebook.com/notesio
Regards;
Notes.io Team