Dry chemistry: its expanded role in doctor's office testing
Free HM, Free AH. The physician's office laboratory is an important adjunct to quality patient care.. Dry chemistry reagents and the instrumentation used with them provide an ideal mechanism to give the patient a timely, relatively inexpensive work-up.. An office laboratory can save the physician and his or her staff many frustrations..
But unless the physician's office laboratory director makes use of the assistance of laboratorians and manufacturers in setting up good quality assurance systems along with the choice of dry chemistry system, the director may merely replace his or her frustrations with new ones.. learn more of an office laboratory are far outweighed by the benefits in quality patient care.. Methods for storing oxidase test reagents.. Barry AL, Bernsohn KL.. Oxidase test reagents are notoriously unstable, but they can be held ready for use if frozen or if reagent-impregnated filter paper is kept dry..
Schneider H, Ziegelasch HJ, Wache HW, Bartels H.. A national standard for anticoagulant therapy.. The Manchester comparative reagent.. Poller L.. Lipid composition of seven APTT reagents in relation to heparin sensitivity..
The phospholipid content of different activated partial thromboplastin time (APTT) reagents was determined and compared to heparin sensitivity.. The seven reagents included were those most widely used amongst participants of the U..K.. National External Quality Assessment Scheme (NEQAS) at the time of study.. NEQAS participants on five plasmas prepared from patients receiving unfractionated heparin..
The concentrations of three neutral lipids and six phospholipids present in the seven APTT reagents were determined by high-performance thin-layer chromatography (HPTLC) and densitometry.. Both the concentrations and the relative percentages of individual phospholipid components varied markedly between reagents.. The total phospholipid Phosphatidylserine (PS) was completely lacking from one reagent prepared from reagents containing extracts from animal tissue.. The concentration of relationship between the concentration of any individual lipid components and heparin sensitivity.. However, the relative percentage phospholipid composition was important since a lower % of PS or phosphatidylinositol (PI) correlated with increasing heparin sensitivity..
Balş MG, Hagiescu L.. thromboplastin time reagent (Pathromtin) from human placenta with those from Matsuoka M, Kobayashi I, Ito M, Sakuragawa N, Jimbo C, Hattori A, Watanabe T, Takahashi K, Hoshiyama M, Iizumi T, Sanada M, Ashizawa T, Takahashi H, Honda H, Shinada S.. Rapid presumptive identification of enterics with reagent impregnated paper strips.. Prevorsek M, Kronish DP, Schwartz BS.. EDTA samples are stable for prothrombin time measurement by combined thromboplastin reagent..
Evaluation of a reagent-impregnated strip for detection of nitrate reduction by bacterial isolates.. Rosegger H, Beitzke A.. Methodical aspects of blood coagulation measurements in birds applying commercial reagents--a pilot study.. Guddorf V, Kummerfeld N, Mischke R.. The aim of this study was to examine the suitability of commercially available reagents for measurements of coagulation parameters in citrated plasma from were used to determine prothrombin time (PT), activated partial thromboplastin time (aPTT) and thrombin time (TT) applying various commercial reagents which are routinely used in coagulation diagnostics in humans and mammals..
A PT reagent based on human placental thromboplastin yielded not only shorter clotting times than a reagent containing recombinant human tissue factor (median and phospholipids of animal origin delivered the shortest clotting times and the lowest range of variation in comparison to three other reagents of different composition.. However, even when this reagent was used, aPTTs were partially origin.. In conclusion, of the commercially available reagents tested, a PT reagent based on human placental thromboplastin and an aPTT reagent including rabbit brain phospholipid and kaolin, show some promise for potential use in birds.. Air contamination of therapeutic drug monitoring assay reagents results in falsely high plasma ammonia levels.. Sagamihara, Japan..
Medicine, Sagamihara, Japan.. BACKGROUND: Accumulating evidence shows that contamination of blood samples by atmospheric ammonia affects blood ammonia test levels; however, reports on the effect of ammonia contamination of assay reagents are limited.. Here, we aimed to clarify the effect of ammonia contamination of assay reagents, particularly the therapeutic drug monitoring (TDM) reagents, on the detection levels of blood ammonia using enzymatic assays.. METHODS: Ammonia gas was measured in the refrigerator compartment of the automatic analyser and the reaction tank water, probe wash water and drain outlets connected to the automatic analyser.. At different time points following the closure of the cold storage, ammonia levels in quality control plasma samples were measured using three commercial assay reagents to evaluate the effect of air contamination..
The distribution of evaporated ammonia in the reagent most affected by air contamination.. RESULTS: It was confirmed that ammonia gas was generated in the cold storage of ammonia, and the highest concentration was detected in the TDM reagent.. The ammonia levels obtained using all three reagents increased significantly after or mixing the reagents by inversion.. CONCLUSIONS: We demonstrated that air contamination by TDM reagents placed in cold storage could result in significantly falsely high ammonia measurements.. Preventing this effect would improve the accuracy of ammonia measurements..
Cervenová O, Sládeková M, Vicianová K.. Discrepant sensitivity of thromboplastin reagents to clotting factor levels explored by the prothrombin time in patients on stable oral anticoagulant treatment: impact on the international normalized ratio system.. BACKGROUND AND OBJECTIVES: We tested the principle of local International Normalized Ratio (INR) calibration using INR calibrator plasmas (PT Calibration Plasma Kit, Behring), two thomboplastin reagents (Neoplastin plus, rabbit brain, Stago, and Recombiplastin, recombinant human tissue factor, Ortho Diagnostics) anticoagulant treatment.. DESIGN AND METHODS: A four-point calibration was obtained with each reagent by between the two reagents (Recombiplastin - Neoplastin Plus) was reduced from PT ratio (using the mean normal prothrombin time as denominator term), INR (using instrument-specific ISI supplied by the manufacturers) and calibrated INR, but there was a consistently significant regression of the differences over the reference thromboplastin and applying Tomenson's correction, but limits of with the two thromboplastin reagents in all plasma samples using immunodepleted plasmas (Stago).. RESULTS: Statistically significant biases were observed for all clotting factors regression of the difference over the average value (after log-transformation, r INTERPRETATION AND CONCLUSIONS: The discrepant sensitivity to factor VII, X and V levels of the two thromboplastin reagents explored in this study prevents INR calibration with commercially available calibrator plasmas and is responsible for a significant variability in INR values even under optimal conditions of INR calibration..
Best blood glucose meters.. Nielsen L, Jørgensen PJ, Hansen AC.. Immunochemical vs guaiac faecal occult blood tests in a population-based screening programme for colorectal cancer.. Ciatto S.. Two faecal occult blood tests (FOBTs), Hemoccult II (guaiac based) and Hemeselect (immunochemical) were compared in a population screening for according to a lower (+ and +/-) and a higher (+) positivity threshold..
A total incidence of colorectal cancer suggest that Hemoccult anticipates cancer superior to Hemoccult as it is at least as effective but more efficient and acceptable than guaiac testing.. click here of Hemeselect cost-effectiveness and sensitivity is needed in order to assess the optimal threshold of positivity and screening frequency.. Development of a simple chromogenic factor VIII assay for clinical use.. Netherlands.. The aim of this study was the development of a simple chromogenic factor VIII least a whole working day..
Here's my website: https://en.wikipedia.org/wiki/Vitamin_A
     
 
what is notes.io
 

Notes.io is a web-based application for taking notes. You can take your notes and share with others people. If you like taking long notes, notes.io is designed for you. To date, over 8,000,000,000 notes created and continuing...

With notes.io;

  • * You can take a note from anywhere and any device with internet connection.
  • * You can share the notes in social platforms (YouTube, Facebook, Twitter, instagram etc.).
  • * You can quickly share your contents without website, blog and e-mail.
  • * You don't need to create any Account to share a note. As you wish you can use quick, easy and best shortened notes with sms, websites, e-mail, or messaging services (WhatsApp, iMessage, Telegram, Signal).
  • * Notes.io has fabulous infrastructure design for a short link and allows you to share the note as an easy and understandable link.

Fast: Notes.io is built for speed and performance. You can take a notes quickly and browse your archive.

Easy: Notes.io doesn’t require installation. Just write and share note!

Short: Notes.io’s url just 8 character. You’ll get shorten link of your note when you want to share. (Ex: notes.io/q )

Free: Notes.io works for 12 years and has been free since the day it was started.


You immediately create your first note and start sharing with the ones you wish. If you want to contact us, you can use the following communication channels;


Email: [email protected]

Twitter: http://twitter.com/notesio

Instagram: http://instagram.com/notes.io

Facebook: http://facebook.com/notesio



Regards;
Notes.io Team

     
 
Shortened Note Link
 
 
Looding Image
 
     
 
Long File
 
 

For written notes was greater than 18KB Unable to shorten.

To be smaller than 18KB, please organize your notes, or sign in.